Ống thép luồn dây điện loại ren IMC CATVANLOI-VIETNAM (CATVANLOI Intermediate Metal Conduit - IMC Steel Conduit) UL 1242

ong thep luon day dien loai ren IMC CVL,steel conduit,gi conduit, panasonic steel conduit,smartube conduit,EMT(Electrical Metallic Tubing,IMC(Intermediate Metal Conduit),RSC(rigid steel conduit),BS4568 steel conduit,BS31 steel conduit,JIS C8305 steel conduit,ống luồn dây điện

Ống thép luồn dây điện loại ren IMC  CATVANLOI 
( CATVANLOI Intermediate Metal Conduit-IMC Steel Conduit)
Tiêu chuẩn ANSI C 80.6/ UL 1242 (USA)
Mã sản phẩm
Product Code
Kích thước
Size
(inch)
Đường kính ngoài
OD
(mm)
Độ dày
Thickness
(mm)
Chiều dài ống
Length
(mm)
IMC12
1/2
20.70
1.79
3030
IMC34
3/4
26.14
1.90
3030
IMC100
1
32.77
2.16
3025
IMC114
1 1/4
41.59
2.16
3025
IMC112
1 1/2
47.81
2.29
3025
IMC200
2
59.93
2.41
3025
IMC212
2 1/2
72.56
3.56
3010
IMC300
3
88.29
3.56
3010
IMC312
3 1/2
100.86
3.56
3005
IMC400
4
113.43
3.56
3005

 

Ứng Dụng Ống Thép Luồn Dây Điện IMC-IMC Steel Conduit:
  • Được lắp đặt cho các khu vực có độ va đập cơ khí cao và một số khu vực chống cháy nổ.
  • Thích hợp cho các công trình dân dụng và các công trình công nghiệp.
Đặc Điểm Ống Thép Luồn Dây Điện IMC-IMC Steel Conduit:
  • Ống thép luồn dây điện IMC là loại ống trung, ren răng được.
  • Ống thép luồn dây điện và các phụ kiện được liên kết với nhau thông qua các khớp ren.
  • Ống thép luồn dây điện IMC được ren sẵn hai đầu theo tiêu chuẩn ANSI / ASME B.1.20.1-1983 (NPT) và kèm theo một khớp nối.
Ưu Điểm Sử Dụng Ống Thép Luồn Dây Điện So Với Ống Luồn Dây Điện PVC:
  • Bảo vệ tốt dây điện.
  • Chống cháy tốt do hệ thống cáp điện/dây điện lão hóa theo thời gian.
  • Tăng tính bảo mật và bảo vệ.
  • Chống nhiễu điện từ.
  • Không cháy và không tạo khói độc khi cháy như ống luồn dây điện PVC. Ở Việt Nam, đa số vụ cháy nhà cao tầng gây nhiều tử vong là do ngạt khói độc xuất hiện trong lúc cháy.
  • Có khả năng tái chế và thân thiện môi trường xanh.
  • Có thể dùng chôn dưới đất.
  • Dễ thay đổi hệ thống đi dây dẫn điện trong tương lai.
  • Chịu được va đập cao.
  • Chi phí cho vòng đời sử dụng thấp.
  • Hệ số giản nở thấp phù hợp sử dụng với vật liệu xây dựng thông dụng.
  • Tương tích với các hóa chất trong bê-tông.
 Vật Liệu Ống Thép Luồn Dây Điện IMC-IMC Steel Conduit: Thép
 
Hoàn Thiện Ống Thép Luồn Dây Điện IMC-IMC Steel Conduit:
  • Mạ điện (Pre- galvanized)
  • Mạ kẽm nhúng nóng (Hot Dip Galvanized) - Theo yêu cầu
Dung Sai Cho Phép Ống Thép Luồn Dây Điện IMC-IMC Steel Conduit:
  • Đường kính ngoài   ± 0.13 mm
  • Chiều dài                 ± 6.00 mm
  • Độ dày                     ± 0.4 mm
Tiêu Chuẩn Áp Dụng Ống Thép Luồn Dây Điện IMC:
  • ANSI C80.6-2005(USA)
  • UL-1242-1983 (USA)

CAT VAN LOI STEEL CONDUIT & FITTINGS CATALOG 2012

DOWNLOAD CVL-STEEL CONDUIT CATALOG

DOWNLOAD BS4568/BS31(BRITISH STANDARD) CERTIFICATES

DOWNLOAD CVL JIS C 8305(JAPAN STANDARD) CERTIFICATES

GUIDELINES FOR CHOOSING SIZE OF CONDUIT

GUIDELINE FOR INSTALL STEELCONDUIT/TUBING

VIDEO HOW TO BEND STEEL CONDUIT

SMARTUBE- CATVANLOI EMT conduit (SMARTUBE-CVL Electrical Metallic Tubing) is made from strip steel, high frequency (ERW) welded. A continuous hot galvanizing process is employed to coat the exterior surfaces evenly and smoothly. A special transparent secondary coating provides further protection against corrosion. Manufactured in accordance with Underwriters Laboratories specification UL-797, American National Standards Institute (ANSI) specification C80.3, and CSA C22.2 No. 83.1. Also conforms to Federal Specifications WW-C-563A, which has been superseded by the UL document. Approved by the National Electric Code article 358, for open, concealed and concrete slab installations.
 
Quality controlled each step of the way - regular tests for weld strength, bendability, plating thickness, all dimensions, and uniform smoothness of interior coating provide you with conduit of the highest quality. SMARTUBE- CATVANLOI EMT conduit (SMARTUBE-CVL Electrical Metallic Tubing)provides perfect bends and offsets that can be made quickly and easily.
 
SMARTUBE- CATVANLOI EMT conduit (SMARTUBE-CVL Electrical Metallic Tubing) uses a special polymer ID coating that has low friction so that feeding wires is simple and quick, providing extra ease in wire installation. No chipping, cracking, peeling - outside surfaces are galvanized with zinc coating for superior corrosion resistance and long-lasting, dependable service. Our conduit products are extremely corrosion resistant and meet all federal and state code requirements.
 
A special protective coating is then applied.
 
Compatible with all types of building materials
Provides a lifetime of safe electrical installations
Low in cost - strong, durable
 
 
HOT ZINC COATED CONDUIT SPECIFICATIONS
 
To specify SMARTUBE-CATVANLOI Hot Zinc Coated EMT include the following: Electrical Conductors shall be enclosed in Western Tube Hot Zinc Coated EMT in accordance with the National Electrical Code. Electric Metallic Tubing shall be steel, electrically welded, hot zinc galvanized and produced to ANSI Specifications C80.3 and to Underwriters Laboratories specification UL-797, and shall carry the Underwriters Laboratories label, as manufactured by Southern Steel Pipe BHD –Malaysia
 
FEATURES AND BENEFITS OF SMARTUBE- CATVANLOI EMT STEEL CONDUIT:
 
  • Consistent Quality – SMARTUBE- CATVANLOI EMT conduit entire production process is solely focused on manufacturing quality products made to our customers' specifications. Because of its ductility and tight tolerances, our EMT promotes wrinkle-free bends, reduces kinking, and minimizes splitting from repeated bending and straightening.
 
  • Cost-Effective Installations – SMARTUBE- CATVANLOI EMT conduit is a thin wall product with more inside wiring space, which means that less product is necessary to purchase.
 
      Easier wire pulling and pushing – diamond-shaped ID pattern and protective, slick, inside coating, reduce friction when pulling / pushing the wires. special protective coating stays hard and smooth in various climate conditions, protecting your conduit and your investment.
 
     Accurate, time-efficient bending – Because ½", ¾", and 1" sizes of SMARTUBE- CATVANLOI EMT conduit are easier to cut and bend properly right away, further reducing waste.
 
 
—  Lower life-cycle costs – steel conduit is impact and fire resistant, chemically compatible with concrete and resists cracking, flaking and damage from severe bending. Its physical and mechanical properties ensure that the pipe has an extended shelf life, great for usage and storage without degradation in quality. Our conduit is also 100% recyclable.
 
Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing approximately 40 percent as much as rigid steel conduit of the same nominal size. EMT can be used for both exposed or concealed work provided that, during installation or afterwards, it is not subjected to severe physical damage. Use of EMT is restricted to systems not exceeding 600 volts and to nonhazardous locations except for Class II Division 2, acceptable in Class III Division 1 and Division 2 per CEC Rule 18-302 (1). Galvanized Steel EMT installed in concrete, on grade or above, generally requires no supplementary corrosion protection. However, when installed in concrete below grade level and in contact with soil or cinders, supplementary corrosion protection consisting of a protective coating of bitumastic or asphalt base paint or plastic is generally applied. EMT run in or under permanently moist cinder fill must be encased in at least two inches of cinder free concrete unless the conduit is at least 18 inches below the fill. Aluminum EMT cannot be directly embedded in concrete containing soluble chlorides such as calcium  chloride, unwashed beach sand, sea water or coral bearing aggregates. When adequately treated with a protective coating of bitumastic or asphalt base paint or plastic coating, the raceway can be installed in concrete containing chlorides. In wet locations where walls are frequently washed or where there are surfaces of absorbent material, the entire wiring system, including boxes, fittings, conduits and cables, must be supported such that there is at least 1/4 inch air space between it and the supporting surface. Fittings and couplings are required to be of concrete tight type when embedded in masonry or concrete or in dry locations and of the rain tight type when installed in wet locations (CEC Rule 12-1410). Where No. 4 or larger underground conductors enter or leave a conduit, an insulating bushing with a smooth well-rounded insulating surface must be provided to protect conductors unless the terminating fitting is quipped with an insulated throat, firmly secured in place providing equivalent protection. The insulating bushing or insulating material must have a temperature rating of not less than the insulation temperature rating of installed conductors. CEC Rule 12-3022 requires that the raceways be metallically joined together into a continuous electric conductor and must be mechanically connected to all boxes, fittings and cabinets as to provide effective electrical continuity. EMT is not permitted to be threaded. Cut ends of tubing are required to be reamed. Code requires that EMT be adequately supported and restricts bends in one run to the equivalent of four quarters or 360 degrees total. Portions of this section reprinted by permission from the Canadian Electrical Code 2009 Part I.

Sản phẩm liên quan

Sản phẩm cung cấp

Cam kết khách hàng

   Các sản phẩm vật tư & thiết bị điện CATVANLOI với giá cả cạnh tranh & dịch vụ khách hàng với chất lượng tốt nhất.

   Liên tục cải tiến chất lượng sản phẩm vật tư & thiết bị điện CATVANLOI & dịch vụ nhằm thoả mãn nhu cầu ngày càng cao của khách hàng.
 
   Giao hàng sản phẩm vật tư & thiết bị điện CATVANLOI trong thời gian ngắn nhất đáp ứng tốt nhất tiến độ thi công.
 
   Luôn duy trì lợi thế cạnh tranh thông qua những sản phẩm vật tư & thiết bị điện CATVANLOI được gia tăng giá trị trong chất lượng và dịch vụ.

  Công ty Thiết bị điện công nghiệp CATVANLOI luôn lắng nghe và thấu hiểu nhu cầu của Khách hàng để đưa ra giải pháp phù hợp.

   Thích ứng nhanh là sức mạnh cạnh tranh của Công ty thiết bị điện công nghiệp CATVANLOI.
 
 

Quảng cáo

Hình 3
Hình 2
Hình 1
Back to Top